Haisi Measurement and Control Technology

IMU300 High-Precision 6-Axis MEMS IMU
PRODUCT PARAMETERS
- 6-axis IMU
- Digital interface: RS422 differential serial port
- High precision, Low noise
- Highly stable accelerometer and gyroscope
- Miniature package, lightweight
- ±500°/s angular rate measurement range
- ±10g acceleration measurement range (optional ranges available)
- Fully configurable parameters and functions
- MEMS-IMU300 Datasheet V1.2.3
Description
Inertial Measurement Unit
The IMU300 is a high-performance, 6-axis Inertial Measurement Unit (IMU) integrating three high-precision MEMS gyroscopes and three high-stability accelerometers. Designed for demanding applications, it delivers reliable and accurate motion sensing in a compact, low-power package, complete with a digital RS422 interface.
IMU300 provides users with several output formats for both the gyroscope and accelerometer, as follows:
- Angular rate
- Incremental angle
- Average angular rate
- Integrated angle
- Acceleration
- Incremental velocity
- Average acceleration
- Integrated velocity
Application Fields:
- Dynamic stabilization platforms
- Aircraft control
- Inertial integrated navigation
- Other scenarios and fields require the measurement of three-axis angular rate and three-axis acceleration of moving objects.
Device Configuration and Self-Diagnostics:
IMU300 utilizes a 32-bit RISC ARM microcontroller. It offers flexible configuration of parameters such as output units, sampling rate, low-pass filter with -3dB frequency, RS422 baud rate, and protocol settings. All configurable parameters can be defined at the time of ordering or set by the customer.
During operation, IMU300 continuously monitors its internal status, and users can access the following monitored parameters:
- Check of internal references
- Check of sensors (error and overload)
- Check of internal temperatures
- Check of RAM and flash
- Check of supply voltage
Host Computer Software Support:
IMU300 supports debugging using host computer software. Through the RS422 interface, the software allows for easy and quick access to measurement data or modification of configuration settings. It also supports data logging and saving to a file.
Composition and Functional Block Diagram:

Performance Specifications and Model Selection:
The performance of the gyroscope for the general-purpose product is detailed in the table below.
Table 1:Gyroscope Specifications Table
| Parameter(gyros) | Conditions | Min | Nom | Max | Unit | Note |
| Full Scale | 500 | deg/s | 1 | |||
| Resolution | 24 | bits | ||||
| Scale Factor | 25℃ | 15000 | Isb/deg/s | Nominal Value | ||
| Scale Factor Repeatability(1σ) | <30 | ppm | 2 | |||
| Scale Factor Nonlinearity(1σ) | <150 | ppm | 3 | |||
| Bandwidth(-3dB) | 16 | 262 | Hz | Configurable | ||
| Sample Rate | 2000 | samples/s | Configurable | |||
| Bias Instability (Allan) | Allan Variance @25°C | <0.3 | deg/h | |||
| Bias Stability@10s | <3 | deg/h | ||||
| Bias Stability @1s | <7.5 | deg/h | ||||
| Bias Temperature Drift(1σ) | <20 | deg/h | Over the full temperature range | |||
| Bias Repeatability(1σ) | <3 | deg/h | ||||
| Broadband Noise | 25℃ | <0.4 | deg/s | |||
| G-Value Sensitivity | <1 | °/hr/g | Three-axis direction | |||
| Vibration Rectification Error(VRE) | (12gRMS,20-2000HZ) | <1 | °/hr/g | |||
| Power-Up Time | 750 | ms |
Note 1: The gyroscope maintains a saturated output state at ±105% FS when exceeding the measurement range.
Note 2: Performance metrics are repeated daily from the specified operating temperature.
Table 2:Accelerometer Specifications Table
| Parameter(accelerometers) | Conditions | Min | Nom | Max | Unit | Note |
| Full Scale | ±10 | g | 4 | |||
| Resolution | 24 | bits | ||||
| Scale Factor Accuracy | Calibration Accuracy | 266 | 270 | 274 | mv/g | |
| Long-Term Scale Factor Stability Scale Factor Temperature Coefficient | @20℃ | 20 | 300 120 | 220 | ppm ppm/℃ | |
| Non-Linearity | IEEE Norm,% of full scale | 0.3 | 1.0 | % | ||
| Bandwidth(-3dB) | 16 | 262 | Hz | Configurable | ||
| Sample Rate | 2000 | samples/s | Configurable | |||
| Bias switch on/off repeatability | 0.75 | mg | ||||
| Bias Stability | 0.15 | mg | ||||
| Bias Error Under Temperature Influence Long-Term Zero Bias Repeatability@20℃ | ΔT ≤ ±1°C/min @1000g @6000g | -2 | ±0.5 1.5 7.5 | 2 | mg/℃ mg mg |
Mechanical dimensions:

Definition of axes:

Pin configuration:

Connection Configuration:

REQUEST A QUOTE
-
Mobile: +86 180 6672 6340
-
Email: sales@haisitek.com
-
WhatsApp: +86 180 6672 6340
FAQs
What interface does the IMU300 use?
What is the bias instability of the IMU300?
Can the output bandwidth be configured?
What is the minimum order quantity and lead time?